Short answer: to size backup power, add up the average watts of the devices you need, multiply by the hours you want them to run, then divide by about 0.85 to cover inverter losses. That gives the battery size in watt-hours (Wh). Separately, make sure the unit’s output rating covers everything running at once, plus the startup surge of any motor.
U.S. electricity customers averaged about 11 hours without power in 2024, almost double the average of the previous decade, according to the U.S. Energy Information Administration (EIA). Most of that time came from hurricanes. To size backup power well, you mostly answer one question: what do you need to keep on, and for how long?
Step 1: List only the essentials
Most people over-buy because they imagine powering the whole house. Start with the short list that actually matters during an outage:
- Refrigerator (and freezer, if separate)
- Internet: modem and Wi-Fi router
- A few LED lights
- Phones and a laptop
- Any device someone in the house depends on (check its manual and your doctor for medical equipment)
Heaters, ovens, dryers and central AC use far more power than a portable unit can sustain. They are a different problem, covered in separate guides.

Step 2: Find each device’s average watts
The label on a device shows its maximum draw. Many devices run well below that most of the time. Three ways to get a better number, from best to worst:
- Measure it with a plug-in power meter for 24 hours. They work with any standard 120-volt plug-in device.
- Use the yearly kWh on the EnergyGuide label (refrigerators and freezers have one). Average watts = kWh per year × 1000 ÷ 8760.
- Use the nameplate watts and an estimate of how many hours it actually runs.
Step 3: Turn watts into watt-hours
The standard formula for daily energy use (as given in Virginia Tech Extension’s energy series) is:
(Watts × Hours used per day) ÷ 1000 = kWh per day
For backup sizing, keep it in watt-hours and use the hours you want to cover:
Energy needed (Wh) = Average watts × Hours of backup

Step 4: Add the losses
A power station stores DC energy and converts it to AC through an inverter, which wastes some energy as heat. Jackery’s published runtime formula, for example, uses an efficiency factor of 0.85. So:
Battery capacity needed (Wh) = Energy needed ÷ 0.85
If you plan to run things from the DC outlets (USB-C, 12 V), losses are smaller, but 0.85 is a safe planning number.
Worked example: fridge, internet and lights for 12 hours
| Device | Average watts | Where the number comes from |
|---|---|---|
| Refrigerator rated 400 kWh/year | 46 W | 400 × 1000 ÷ 8760 |
| Modem + Wi-Fi router | 13 W | Measured averages published by Ericsson (12.7 W) and Prysmian (~13 W) |
| Three 9 W LED bulbs | 27 W | Bulb label |
| Total | 86 W |
Energy for 12 hours: 86 W × 12 h = 1,032 Wh. Battery needed: 1,032 ÷ 0.85 ≈ 1,214 Wh. A unit around 1,200–1,500 Wh covers this with some margin. A 1,000 Wh unit would run the same list for about 10 hours.

Size backup power by outage length
The same 86 W essentials list needs very different batteries depending on how long you plan to ride out. Battery Wh = 86 W × hours ÷ 0.85:
| Outage you plan for | Energy used | Battery to size backup power for |
|---|---|---|
| 4 hours | 344 Wh | about 405 Wh |
| 8 hours | 688 Wh | about 809 Wh |
| 12 hours | 1,032 Wh | about 1,214 Wh |
| 24 hours | 2,064 Wh | about 2,428 Wh |
| 48 hours | 4,128 Wh | about 4,856 Wh |
The EIA’s 2024 national average of about 11 hours without power sits near the 12-hour row, but averages hide long storm outages. Beyond about a day, recharging (solar panels, a car, or a generator run safely outdoors) usually makes more sense than buying a bigger battery. Our power station vs gas generator comparison covers that trade-off.
Step 5: Check the output rating and the surge rating
Capacity (Wh) is how long. Output (W) is how much at once. Two checks:
- Continuous output must exceed the total of everything that can run at the same time.
- Surge (peak) output must cover the brief startup spike of motors and compressors, such as a refrigerator. The spike lasts a fraction of a second but can be several times the running draw. If the manual does not list it, a power meter with a peak reading will show it.
Common mistakes when you size backup power
- Using nameplate watts for a fridge. The compressor cycles on and off. Virginia Tech Extension’s energy guide suggests dividing a refrigerator’s plugged-in time by three to estimate the hours it runs at full wattage.
- Forgetting the power station’s own draw. Leaving the AC inverter on with nothing plugged in still uses energy.
- Ignoring temperature. Batteries deliver less in cold rooms, and fridges work harder in hot ones.
Try it with your own numbers
Use the Power Station Runtime Calculator. It applies these same formulas and shows each step.
FAQ
Is a bigger power station always better?
No. Past the size your essentials need, you pay for capacity you won’t use and carry more weight. Size for your longest realistic outage, then decide whether expansion batteries or solar recharging make more sense than one huge unit.
Can I size for a whole day?
Yes. Multiply the average watts by 24. For the example above, that is 86 × 24 ÷ 0.85 ≈ 2,430 Wh.
Should I trust the runtime chart on the box?
Treat it as a best case. Charts often assume lab conditions. Your own measured watts and the formula above give a more realistic number.
Sources: EIA, 2024 outage data; Virginia Tech Extension, Estimating Appliance and Home Electronic Energy Use; Jackery runtime formula; Ericsson home measurements. Calculations by Lucas, Electrical Engineer. No products were tested for this guide.